DIN Pn16 Flanged Ci Di Ductile Iron Ball Type Check Valve Ball Valve Electric Butterfly Valve Siemens Actuator Globe Valve
The company takes the promotion of Hot Water Absorption Chiller, Vacuum Pump PVD N360-1, Chiller Solution Filter preparation level as its own responsibility, and always puts independent technology research and development and product innovation and transformation at an important position in enterprise development. In order to ensure customer satisfaction, we use expert-level services, tailor-made for customers, and provide a full range of product solutions. We have established a computerized customer file system to ensure a rapid response to customer needs. We are actively looking for low-cost, good quality production technology and reliable equipment.
Zhenjiang Fulaier Refrigeration Engineering Technology Co., Ltd. was established in 2003. It is a professional technical service enterprise integrating central air-conditioning host sales, spare parts sales, and unit repair and maintenance.
The company's main business scope includes: custom processing of lithium bromide solution; sales of lithium bromide special filters; sales of central air-conditioning chillers; sales of various parts of central air-conditioning.

Siemens actuator
Electro-hydraulic actuators for valves SKC32 SKC82 SKC62 SKC60
SKC32 working voltage AC 230V three-position control signal
SKC82 working voltage AC 24V three-position control signal
SKC6 working voltage AC 24V control signal DC 0-10V, 4-20mA or 0-1000Ω
SKC6 has flow characteristics selection, position feedback, stroke calibration, LED status indicator, priority control function
SKC62UA has the following functions: running direction, stroke limit control, sequence control with adjustable starting point and range of action, action according to the antifreeze protection monitor QAF21 and QAF61 signals
Driving force 2800N
Actuator model (with or without spring return function)
Installed directly on the valve without adjustment
Manual adjustment and valve position indicator
Optional functions: auxiliary switch, potentiometer, stem heater and mechanical stroke inverter
SKC U has passed UL certification
Standard electronic module
Principle of electro-hydraulic actuator
Open the valve. The hydraulic pump (6) pushes the hydraulic oil in the oil storage chamber (3) to flow into the pressure chamber (8), thereby moving the pressure cylinder (2) downward. The valve stem (11) contracts and the valve opens. At the same time, the return spring (4) is compressed.
Close the valve. Actuating the solenoid valve (5) allows the hydraulic oil in the pressure chamber to flow back to the oil storage chamber. The compressed spring is released to push the pressure cylinder upward. The valve stem is extended and the valve is closed.
Manual operation mode. Turn the manual regulator (1) clockwise to move the pressure cylinder down and open the valve. At the same time, the return spring is compressed.
In manual operation mode, the control signals Y and Z can further open the valve, but cannot move to the "0%" stroke position of the valve. If you want to set the position manually, turn off the power or interrupt the control signals Y and Z, the "MAN" red indicator light will be on.
Note: Controller for manual operation. When setting the controller for manual operation for a longer period of time, it is recommended to adjust the actuator to the desired position through manual adjustment. This ensures that the actuator remains in this position during this period of time. Note: When the controller is set to automatic control, don't forget to switch to automatic operation.
Automatic mode. Rotate the manual adjuster counterclockwise to the end limit. The pressure cylinder moves up to the "0%" stroke position of the valve. The red indicator light marked "MAN" goes out.
Minimum volume flow. The actuator can be manually adjusted to a stroke position> 0% for applications that require a constant minimum volume flow.
Spring return function. SKC32.61, SKC82.61... and SKC62... actuators have a spring return function and are equipped with a solenoid valve that opens when the control signal is lost or power is cut off. The return spring makes the actuator return to the "0%" stroke position and closes the valve, which meets the safety requirements of DIN 32730.
Technical parameters
Size
Siemens valve body
Basic technical parameters
●Valves with medium temperature of -10…150℃
● The valve body is gray cast iron EN-GJL-250 or above
● DN 25…150
● k vs 6.3…400 m 3 /h
● Flange type 21, flange design is B
● VVF42..KC, with pressure compensation function, suitable for high pressure difference applications
● It can be equipped with electric actuator SAX.. or electric hydraulic actuator SKD.., SKB.., SKC..
Application: As a regulating or shut-off valve, used in boilers, central heating and refrigeration equipment, cooling towers, heating equipment, ventilation and air handling units.
Dimensions
Installation
Product display

Our perfect management system and rich production experience make our DIN Pn16 Flanged Ci Di Ductile Iron Ball Type Check Valve Ball Valve Electric Butterfly Valve Siemens Actuator Globe Valve have excellent quality. We turn the pressure and challenges we face into motivation and opportunities, and move forward towards our goals. We are committed to ethical business practices, relentless pursuit of quality, technical integrity, and responsibility for our employees.