Our company is based in China, facing the world, providing satisfactory Sanyo Shell And Tube Heat Exchanger, Absorption Chiller, Vacuum Pump PVD N360-1 to customers around the world, and cooperating with many manufacturers to jointly develop the market. We always adhere to the mission of "creating wealth for society, creating value for customers, and creating a happy home for employees", and always adhere to the concept of "customer-centric, innovation-driven, and repaying society as our responsibility". The ultimate goal of our company's production scheduling is to meet customer needs and maximize profits. We continue to strengthen the market concept and adhere to the market trend as the guide. We continue to strengthen our technical force to achieve reductions in staff and efficiency, optimize labor costs, and improve operational efficiency.
Zhenjiang Fulaier Refrigeration Engineering Technology Co., Ltd. was established in 2003. It is a professional technical service enterprise integrating central air-conditioning host sales, spare parts sales, and unit repair and maintenance.
The company's main business scope includes: custom processing of lithium bromide solution; sales of lithium bromide special filters; sales of central air-conditioning chillers; sales of various parts of central air-conditioning.

Siemens actuator
Electro-hydraulic actuators for valves SKC32 SKC82 SKC62 SKC60
SKC32 working voltage AC 230V three-position control signal
SKC82 working voltage AC 24V three-position control signal
SKC6 working voltage AC 24V control signal DC 0-10V, 4-20mA or 0-1000Ω
SKC6 has flow characteristics selection, position feedback, stroke calibration, LED status indicator, priority control function
SKC62UA has the following functions: running direction, stroke limit control, sequence control with adjustable starting point and range of action, action according to the antifreeze protection monitor QAF21 and QAF61 signals
Driving force 2800N
Actuator model (with or without spring return function)
Installed directly on the valve without adjustment
Manual adjustment and valve position indicator
Optional functions: auxiliary switch, potentiometer, stem heater and mechanical stroke inverter
SKC U has passed UL certification
Standard electronic module
Principle of electro-hydraulic actuator
Open the valve. The hydraulic pump (6) pushes the hydraulic oil in the oil storage chamber (3) to flow into the pressure chamber (8), thereby moving the pressure cylinder (2) downward. The valve stem (11) contracts and the valve opens. At the same time, the return spring (4) is compressed.
Close the valve. Actuating the solenoid valve (5) allows the hydraulic oil in the pressure chamber to flow back to the oil storage chamber. The compressed spring is released to push the pressure cylinder upward. The valve stem is extended and the valve is closed.
Manual operation mode. Turn the manual regulator (1) clockwise to move the pressure cylinder down and open the valve. At the same time, the return spring is compressed.
In manual operation mode, the control signals Y and Z can further open the valve, but cannot move to the "0%" stroke position of the valve. If you want to set the position manually, turn off the power or interrupt the control signals Y and Z, the "MAN" red indicator light will be on.
Note: Controller for manual operation. When setting the controller for manual operation for a longer period of time, it is recommended to adjust the actuator to the desired position through manual adjustment. This ensures that the actuator remains in this position during this period of time. Note: When the controller is set to automatic control, don't forget to switch to automatic operation.
Automatic mode. Rotate the manual adjuster counterclockwise to the end limit. The pressure cylinder moves up to the "0%" stroke position of the valve. The red indicator light marked "MAN" goes out.
Minimum volume flow. The actuator can be manually adjusted to a stroke position> 0% for applications that require a constant minimum volume flow.
Spring return function. SKC32.61, SKC82.61... and SKC62... actuators have a spring return function and are equipped with a solenoid valve that opens when the control signal is lost or power is cut off. The return spring makes the actuator return to the "0%" stroke position and closes the valve, which meets the safety requirements of DIN 32730.
Technical parameters
Size
Siemens valve body
Basic technical parameters
●Valves with medium temperature of -10…150℃
● The valve body is gray cast iron EN-GJL-250 or above
● DN 25…150
● k vs 6.3…400 m 3 /h
● Flange type 21, flange design is B
● VVF42..KC, with pressure compensation function, suitable for high pressure difference applications
● It can be equipped with electric actuator SAX.. or electric hydraulic actuator SKD.., SKB.., SKC..
Application: As a regulating or shut-off valve, used in boilers, central heating and refrigeration equipment, cooling towers, heating equipment, ventilation and air handling units.
Dimensions
Installation
Product display

In order to gain competitive advantage in the market and enhance the core competencies of competition, we should significantly improve our Siemens Temperature Control Valve Is a Typical Application of Electric Flow Control Valve in The Field of Temperature Control and production capacity in the future. We have a high-quality team, strong product research and development capabilities, rich product knowledge and targeted design to fully meet the needs of users. To make our products fine and reputable brand is the goal of our enterprise.