Small Size Absorption Chiller

Small Size Absorption Chiller

The canned motor pump plays the role of conveying medium in the unit. The canned motor pump whose conveying medium is refrigerant water is called refrigerant pump, and the canned motor pump whose conveying medium is lithium bromide solution is called solution pump.
Send Inquiry
Product Introduction

We always concentrate our attention on the research and development, production and sales of the Copper Pipe For Refrigeration, Finned Tube Plate Heat Exchanger, LG Steam Type Absorption Chiller, we warmly welcome our customers from home and abroad to visit us! Our company insists on the attitude of honesty, pragmatic style and win-win purpose, and is willing to work hand in hand with our customers to create new brilliance. After years of operation and high-quality after-sales service, our company has a place in the market, and has been trusted and supported by some big customers. The company provides customers with high-quality professional technical services and strives to become an enterprise trusted by customers and respected by the society. Scientific and technological innovation is the power source of regional economic development and industrial technological progress.

Zhenjiang Fulaier Refrigeration Engineering Technology Co., Ltd. was established in 2003. It is a professional technical service enterprise integrating central air-conditioning host sales, spare parts sales, and unit repair and maintenance.

The company's main business scope includes: custom processing of lithium bromide solution; sales of lithium bromide special filters; sales of central air-conditioning chillers; sales of various parts of central air-conditioning.


1


The canned motor pump plays the role of conveying medium in the unit. The canned motor pump whose conveying medium is refrigerant water is called refrigerant pump, and the canned motor pump whose conveying medium is lithium bromide solution is called solution pump. The canned motor pump is extremely important in the unit. part.

The canned motor pump is a non-leakage pump, with an integrated structure of the motor and the pump, so that the electric pump is completely leak-free. The appearance and internal structure of different models of canned motor pumps of different brands are quite different, but their working principles are similar.

The canned motor pump has absolutely no leakage, and the outside air will not be sucked in the negative pressure in the pump, which is especially suitable for vacuum system operation.


Commonly used fragile accessories matching

2(4).jpg


High-quality choice, four advantages

Long life/low power consumption/no leakage/high vacuum

Canned motor pump-Nikkiso


Product details

6(15).jpg


Japanese machine installed pump: SS211-2.2H-C002

Head 14m, flow 167L/min

Power 1.8KW Frequency 50HZ

Rated current 5A Rated voltage 380V


Japanese machine installed pump: SS221-3.7H-C004

Head 7m, flow 500L/min

Power 3.2KW Frequency 50HZ

Rated current 7.5A Rated voltage 380V


Japanese machine installed pump: S291-1.5H-C015

Head 4m, flow 300L/min

Power 1.5KW Frequency 50HZ

Rated current 5A Rated voltage 380V


Japanese machine installed pump: SS230-3.7H-C010

Head 14m, flow 400L/min

Power 3.7KW Frequency 50HZ

Rated current 8.5A Rated voltage 380V


Japanese machine installed pump: SS491-3.7H-C009

Head 7m, flow 1000L/min

Power 2.6KW Frequency 50HZ

Rated current 10A Rated voltage 380V


Japanese machine installed pump: 16DNS0L002

Head 13.5m flow 350L/min

Power 3KW Frequency 50HZ

Rated current 8.2A Rated voltage 380V

Canned motor pump-Shanghai


Parameter description

9


Shanghai Pump: PN2-0.75-4C10-7

Head 7m, flow 10m3/H

Power 0.75KW Frequency 50HZ

Rated current 2.8A Rated voltage 380V

Transmission medium temperature ≤95 cavitation allowance 0.5m


Shanghai Pump: PN2-1.1-4C10-7

Head 7m, flow 10m3/H

Power 1.1KW Frequency 50HZ

Rated current 3.5A Rated voltage 380V

Transmission medium temperature ≤95 cavitation allowance 0.5m


Shanghai Pump: PN2-1.5-4C30-7

Head 7m, flow 30m3/H

Power 1.5KW Frequency 50HZ

Rated current 4.5A Rated voltage 380V

Transmission medium temperature ≤95 cavitation allowance 0.5m


Shanghai Pump: PN2-2.2-4C30-7

Head 7m, flow 30m3/H

Power 2.2KW Frequency 50HZ

Rated current 5.99A Rated voltage 380V

Transmission medium temperature ≤95 cavitation allowance 0.5m


Shanghai Pump: PN2-3.7-4C20-14

Head 14m Flow 20m3/H

Power 3.7KW Frequency 50HZ

Rated current 10A Rated voltage 380V

Transmission medium temperature ≤95 cavitation allowance 0.5m


Shanghai Pump: PN2-5.5-4C18-22

Head 22m Flow 18m3/H

Power 5.5KW Frequency 50HZ

Rated current 14A Rated voltage 380V

Transmission medium temperature ≤95 cavitation allowance 0.5m


Shanghai Pump: PN2-7.5-4C40-19

Head 19m, flow 40m3/H

Power 7.5KW Frequency 50HZ

18A rated voltage 380V

Transmission medium temperature ≤95 cavitation allowance 0.5m


Shanghai Pump: PN2-9-4C70-14

Head 14m, flow 70m3/H

Power 9KW Frequency 50HZ

Rated current 21A Rated voltage 380V

Transmission medium temperature ≤95 cavitation allowance 0.5m

Canned motor pump-Carrier


Product details

8(4).jpg


Carrier pump: 16DNL055C-2CH-30SG-1

Power 5.5KW Rated current 15A

Rated voltage 380V Frequency 50HZ


Carrier pump: 16DNL066C-2CH-30SG-1

Power 7.5KW Rated current 18A

Rated voltage 380V Frequency 50HZ


Carrier pump: 16JT080-1701L

Power 3.7KW Rated current 10.5A

Rated voltage 380V Frequency 50HZ


Carrier pump: 16JT090-1701L

Power 4.8KW Rated current 14A

Rated voltage 380V Frequency 50HZ


Carrier pump: 16JT100-1601L

Power 1.5KW Rated current A

Rated voltage 380V Frequency 50HZ


Carrier pump: 16JT847-1701L

Power 5.5KW Rated current 15A

Rated voltage 380V Frequency 50HZ


Carrier pump: 16JT857-1601L

Power 1.5KW Rated current 4.6A

Rated voltage 380V Frequency 50HZ


Canned motor pump-Ebara

Product details

8(3).jpg


Ebara Pump: RCD 025-9954

Power 3.2KW Rated current 9A

Rated voltage 380V Frequency 50HZ


Ebara Pump: 16JAH040-6754X2

Power 0.75KW Rated current 2.6A

Rated voltage 380V Frequency 50HZ


Ebara pump: 16J AH064-6754X2

Power 3.7KW Rated current 10A

Rated voltage 380V Frequency 50HZ


Ebara pump: 16J CD060-9954

Power 5.5KW Rated current 12.5A

Rated voltage 380V Frequency 50HZ


Ebara pump: 16J AW110-6754X2

Power 1.5KW Rated current 4.9A

Rated voltage 380V Frequency 50HZ


Ebara Pump: RCD CD040-9954

Power 3.7KW Rated current 10A

Rated voltage 380V Frequency 50HZ


Canned motor pump failure and its cause and discharge method

16


The company has become a member of China's Small Size Absorption Chiller equipment industry with the purpose of being sincere and casting the future. Our commitment to quality and efficient service has played an important role in many years of practice and has won universal praise from the market and customers. We are people-oriented, we manage and rectify, deeply carry out the internal management of the enterprise, take technological progress as the guide and pay close attention to product quality, so that our company enjoys a high reputation.

Send Inquiry

whatsapp

Phone

E-mail

Inquiry