Absorption Chiller, Ebara

Absorption Chiller, Ebara

Advanced energy saving measures.
Compact structure, small size, integrated main components.
Unique series-parallel process.
Send Inquiry
Product Introduction

We are committed to integrity and service. In the future, we will cherish the trust of customers, continue to optimize products and improve service levels, and return customers with high-quality Carrier Direct-fired Absorption Chiller, LG Hot Water Absorption Chiller, Steam Type Absorption Chiller. Customer satisfaction is the highest guiding principle of our business. We are willing to sincerely cooperate with you with high-quality products, reasonable prices, timely delivery and perfect services! We are guided by the business philosophy of "Being Honest and Honest", We sincerely hope to make friends with domestic and foreign manufacturers, go hand in hand, and create brilliance together! We evolve the corporate philosophy of high-quality products and star-rated services into the surging driving force for sustainable development of the company.

Absorption chillers are usually divided into steam type, direct-fired type and hot water type

Ebara Steam Double-Effect Refrigerator


Direct-fired absorption chiller and warmer

4


Especially suitable for special industrial fields such as coking, steel, lysine, food, chemical industry, etc.


Feature

1. Advanced energy saving measures.

2. Compact structure, small size, integrated main components.

3. Unique series-parallel process.

4. Dedicated anti-crystallization system.

5. Perfect control system.

6. Advanced air extraction device.

7. The real green environmental protection air conditioner.

8. The lithium bromide solution is highly efficient, environmentally friendly, and does not need to be replaced for life.

9. Ultra-low pressure nozzle spray technology.

10. Special burner for direct combustion engine.


Principle of refrigeration


Salient features:

Low-carbon emission reduction: waste heat and waste heat steam can be used as heat sources to achieve low-carbon technology and environmental protection.

High efficiency and energy saving: Adopt plate heat exchanger to strengthen heat exchange and improve thermal efficiency; multi-stage heat recovery to improve unit performance;

Green and environmental protection: Use environmentally friendly lithium molybdate corrosion inhibitor to ensure vacuum, and the equipment can achieve seasonal air extraction.


How it works

The cold water in the evaporator is cooled by the low-temperature refrigerant water after the decompression and throttling from the condenser. The refrigerant water itself absorbs the heat of the cold water and evaporates to become refrigerant vapor. It enters the absorber and is absorbed by the solution. The concentrated solution becomes Dilute solution.

The dilute solution in the absorber is pumped to the heat exchanger and heat recovery device, and then the temperature rises, and finally enters the regenerator, where the dilute solution is heated and concentrated into a concentrated solution. The concentrated solution passes through the heat exchanger, the temperature drops, enters the absorber, drips on the cooling water pipe, absorbs the refrigerant vapor from the evaporator, and becomes a dilute solution. On the other hand, in the regenerator, the water vapor generated after the lithium bromide solution is heated by external steam enters the condenser to be cooled, and after decompression and throttling, it becomes low-temperature refrigerant water, which enters the evaporator, and drops on the cold water pipe. , To cool the cold water entering the evaporator.

The above cycle is repeated so as to finally achieve the purpose of preparing low-temperature cold water.


Hoisting essentials

8


1. Hoisting operations must be performed by a holder of a hoisting operation permit.

2. Please use a lifting device (hook, wire rope, shackle) that meets the strength after confirming the lifting weight. Please refer to the outline drawing for weight and size.

3. Please insert the hook and loop into the hoisting hole, hang the wire rope and use four-point hoisting, so that the hoisting angle is below 60

4. Carry out the lifting operation carefully, and be careful not to damage all parts of the refrigerator. When the wire rope touches the vulnerable part, please adjust the length of the wire rope or pave the flexible material for proper treatment. Particular attention should be paid to small pipes, wiring instruments and other subtle points.

5. Hoisting and landing must make the unit level, especially when landing, make the refrigerating machine feet all contact the ground at the same time.


9(15).JPG


We have enjoyed a high reputation in the Absorption Chiller, Ebara industry for our corporate image based on high-end customer service. With high technical resistance and advanced processing equipment, we are firmly in the position of leader in the industry. In order to adapt to the current development mode of market economy, our company actively expands new business areas and takes effective measures to optimize and reform our own operation management system, so as to continuously improve efficiency and gain competitive advantage.