Lithium Bromide Shell and Tube Heat Exchanger
video

Lithium Bromide Shell and Tube Heat Exchanger

Flier has been continuously introducing advanced manufacturing equipment to meet the needs of different customers in terms of production technology.
Send Inquiry
Product Introduction

                                                                Lithium Bromide Shell and Tube Heat Exchanger


Flier has been continuously introducing advanced manufacturing equipment to meet the needs of different customers in terms of production technology.


2(5).jpg



The heat exchanger is one of the important parts of central air conditioning. Flyer has a strong team of professional and technical personnel and professional production equipment to customize various high-temperature heat exchangers, low-temperature heat exchangers, condensate heat recovery devices and other heat exchange devices for customers in central air conditioning.


3(7).JPG


The generator includes high temperature regenerator, low temperature regenerator, furnace, etc. To a large extent, the customized processing of the generator provides great convenience for the realization of the unit transformation.


4(2).png


Custom processing instructions:

Customized project types: high temperature heat exchangers, low temperature heat exchangers, condensate heat exchangers, high temperature generators, etc.

Customized specifications and sizes: Provide customized processing drawings or physical photos and sizes.

Custom required materials: copper pipes, stainless steel pipes, copper-nickel alloy pipes, iron pipes, etc.

Copper tube type: tube flower tube (pitted tube), corrugated tube, fin tube, smooth tube, etc.


Production cycle

7(4).jpg


Light tube ordering cycle: 7-10 days

Order time for knurled tube: 15-20 days

Exchanger production cycle: 15-20 days

High-speed generator production later period: 30-40 days

The production cycle of other special processed products needs to be confirmed according to the work content and difficulty production plan.


Product display

Heat exchanger

8(6).JPG


Condensate heat exchanger

11(9).JPG


High hair furnace

10(7).jpg


Customized processing site construction

8(7).JPG


Shell and tube heat exchanger. Also known as steam-water fast heat exchanger. The heat exchanger is equipped with many heat exchange tubes in the cylinder (shell). The outside of the tube is steamed and the inside of the tube is heated water. The flow rate of water is generally between 0.5-2.0m/s, and the recommended flow rate is 1.0-1.5m/s. The heat exchange tubes can be seamless steel pipes, but copper pipes are mostly used. In order to ensure that the water flow rate is within a reasonable range, for large flow occasions, the method of reducing the number of return passes of the coil can be used to reduce the flow rate and also reduce the water resistance. On the contrary, the number of return trips can be increased.

There are also many types of shell and tube heat exchangers. There are fixed tube sheets, shell-and-tube heat exchangers with expansion joints; shell-and-tube heat exchangers with U-tubes and shell-and-tube heat exchangers with floating heads. Because the floating head heat exchanger solves the problem of thermal expansion and is more convenient to manufacture, clean and repair, it is the most widely used in this type of heat exchanger. In addition, shell-and-tube heat exchangers also have the form of water-water exchange, which is often used in steam condensate heat recovery systems.

The heat transfer coefficient K value of the shell-and-tube heat exchanger: for steam-water heat exchangers, when the heat exchange tube is steel pipe, K=1.40-2.40KW/(m2*k); when the heat exchange tube is copper tube, K=1.75-3.26KW/(m2*k); when used for water-water heat exchange, the K value drops to 0.58-1.05KW/(m2*k).


Selection of heat exchange equipment

In the air-conditioning water system, the correct choice of heat exchanger is essential for the normal and safe operation of the system. Generally, the following aspects should be considered:

1. Selection of the type of heat exchanger. The type selection should be considered according to its use requirements. In the air-conditioning water system, steam-water and water-water heat exchangers are commonly used. Water-to-water heat exchange can be divided into two kinds of heat exchanges between high-temperature hot water and hot water for air conditioning and cold water (low-temperature water).

In the selection of steam-water heat exchangers, the price of plate type and spiral plate type is higher, and the price of shell-and-tube type and floating coil type is moderate. When selecting heat exchangers for high-temperature hot water (95/70℃) and air-conditioning hot water (60/50℃), the heat exchange area required for calculation is generally larger, so the shell-and-tube type is not suitable. It is a cheaper spiral plate and floating coil heat exchanger. In the heat exchange process between low temperature and cold water, because the heat transfer temperature difference is small, it must have a large heat exchange area. The plate heat exchanger is the most suitable one of all heat exchangers. The other three heat exchangers can't achieve the effect it has, and its price alone is also the most expensive.

2. The heat transfer area of the heat exchanger can be calculated by the formula, but the calculation of the heat transfer coefficient is more complicated. You can consult the relevant product samples or information, or you can assist in the calculation. The selected heat exchange area should have a certain margin than the calculated value, generally 15%-20%.

3. The working pressure of the heat exchanger must be able to meet the maximum pressure requirement when the system is running or static. This is also the basic requirement to ensure the system works.

4. If the heating medium is steam or high-temperature hot water, pay attention to the type of heat exchanger sealing gasket and ensure its service life.

5. When choosing a heat exchanger, pay attention to the resistance loss on the water side. When the resistance is too large, it will increase the energy consumption of the circulating pump, or it will not match the pressure head of the water supply system, resulting in insufficient water and affecting the normal use of the system. When using a heat exchanger with automatic control, you must also pay attention to the resistance loss of the automatic control valve. For the water system using plate heat exchangers, because the gap between the heat exchangers is small, in order to protect it from clogging, Wangwang configures a filter with a smaller pore size on the water pipeline, so the resistance should not be ignored. The sum of the resistance losses of these devices must be less than or equal to the pressure head of the system.



Lithium bromide solution manufacturer

 

About us

Flier Refrigeration Engineering Technology Co., Ltd is a professional technical service enterprise integrating central air-conditioning host sales, spare parts sales, unit repair and maintenance.

Factory located in Zhenjiang, Jiangsu, covering an area of 25,000 square meters ,and has been built with 1 R&D center, 1 pilot plant, 3 An innovative production, learning, and research base composed of a professional production workshop and its corresponding infrastructure. At present, the company has become a well-known technical service provider in the field of central air conditioning in China.

The company’s main business scope includes: central air-conditioning maintenance, cleaning and technical services; cooling tower and fan coil cleaning and maintenance services; custom processing of lithium bromide solution; sales of lithium bromide solution special impurity separators; central air-conditioning host and various zero Sales of accessories; installation and sales of central air conditioning systems, etc.

Contact us

Ms. Lillian GUO

Zhenjiang FLIER Refrigeration Engineering Technology Co., Ltd

Jiangsu, China

Tel: + 86 153588768(Whatsapp/Wechat)

E-mail: mdguolijuan@zjflier.com


Hot Tags: lithium bromide shell and tube heat exchanger, China, suppliers, manufacturers, customized, cheap, used, high quality, Rotary Vane Vacuum Pump, Shell And Tube For Shuangliang Chiller, Finned Tube Plate Heat Exchanger, Sanyo Shell And Tube Heat Exchanger, Lithium Bromide Shell And Tube Heat Exchanger

Send Inquiry

whatsapp

Phone

E-mail