The importance of maintenance during the operation of chillers

The importance of maintenance during the operation of chillers

In a high-temperature environment, the unit is in a high load operating state, and some small faults will gradually appear during operation. At this time, maintenance during unit operation will be particularly important.

01

Technicians will analyze and judge potential problems of the unit based on various data during high load operation, in order to eliminate hidden dangers and ensure the stable operation of the refrigeration unit.

The sudden failure of the unit during operation is largely due to external factors such as cooling water temperature, cooling water flow rate, chilled water flow rate, steam temperature, pressure, and unit vacuum during startup. These factors can worsen the operating conditions of the unit. If not detected in a timely manner, the refrigeration effect of the unit will be greatly affected, and even a fault alarm will appear, leading to shutdown.

If these problems can be detected in a timely manner during the operation of the unit, it can greatly avoid the expansion of the problem, thereby reducing the failure rate of unit operation.

02

The maintenance work during startup is mainly aimed at monitoring the data during the operation of the unit, adjusting the operating status of the unit in a timely manner, and ensuring the efficient and stable operation of the unit.

Below, we will share some precautions and maintenance methods related to the operation of refrigeration units. Please pay attention to them:

01 Vacuum state

03

Pay close attention to the vacuum rebound (pressure increase in the air storage chamber) of the unit every day, record the frequency of vacuum pumping, and promptly contact our technical personnel if any abnormal vacuum is found in the unit;

02 Cooling water quality monitoring

Strictly control the water quality of the cooling water system and monitor basic indicators such as pH and alkalinity. At the same time, due to the use of open circulation in cooling water, the concentration factor corresponding to high cooling water temperature in summer is easily too high, making the cooling water quality too hard, and the water chamber of the unit prone to scale, resulting in poor heat exchange of the unit;

03 Electrical control protection

The electronic components inside the electric control cabinet of the unit will have a significant increase in failure rate when operating in a high-temperature environment for a long time. Therefore, during the operation of the unit, the electric control cabinet must take ventilation and heat dissipation measures to ensure the stable operation of the electronic control part;

04 Unit temperature and liquid level

The unit temperature includes the temperature of the molten crystal tube, the temperature of the dilute solution, the temperature of the high-temperature generator, and the condensation temperature.

The unit liquid level includes the evaporator liquid level and the absorber liquid level.

If there are abnormal changes in the temperature and liquid level of the unit, immediately check whether the vacuum degree of the unit is normal. If it cannot be resolved, please contact our technical personnel in a timely manner;

05 Cooling water temperature and flow rate

When the cooling water temperature is too high in summer, the absorption effect of the unit will deteriorate, leading to a decrease in the cooling capacity of the unit. Relevant personnel should promptly check the normal operation of the cooling tower fan, and can also use methods such as increasing the cooling water flow rate of the unit or replacing some of the cooling water inside the cooling tower to achieve the goal of increasing the cooling capacity of the unit.

A low cooling water flow rate can cause a large amount of heat to accumulate inside the unit, resulting in poor refrigeration. Controlling the cooling water flow rate is a necessary factor to ensure stable operation of the unit.

summary

05

The smooth operation of the refrigeration unit depends on the reasonable and stable operating conditions of the refrigeration unit and the correct use and maintenance of the unit.

The air conditioning system bears the responsibility of creating and maintaining a comfortable and healthy indoor environment. In order to ensure its use, minimize energy consumption, and reduce equipment failure rates, unit managers must carefully understand the maintenance knowledge related to refrigeration units.

06

Production Application

 

The company’s main business scope includes: central air-conditioning maintenance, cleaning and technical services; cooling tower and fan coil cleaning and maintenance services; custom processing of lithium bromide solution; sales of lithium bromide solution special impurity separators; central air-conditioning host and various zero Sales of accessories; installation and sales of central air conditioning systems, etc.

Widely used in major air-conditioning systems and process refrigeration cold and heat sources; in steel, textile, chemical, electronics, pharmaceutical, food and other industrial and mining enterprises, as well as hotels, theaters, hospitals, and large commercial buildings , Central heating stations and other occasions are widely used.

 